35kv Oil-Immersed Power Transformer
20000KVA 35KV
20000KVA 35KV
3150KVA 35KV
| Rated capacity (KVA) |
Voltage combination | Join group label | No-load loss (W) |
Load loss (W) |
Short-circuit impedance (%) |
No-load current (%) |
||
| High tension (KV) |
Tapoff % |
Low pressure (KV) |
||||||
| S13-50/35 | 38.5 35 |
±5 ±2x2.5 |
0.4 | Dyn11 Yyn0 |
128 | 1200/1140 | 6.5 | 1.30 |
| S13-100/35 | 184 | 2010/1910 | 1.10 | |||||
| S13-125/35 | 216 | 2370/2260 | 1.10 | |||||
| S13-160/35 | 224 | 2820/2680 | 1.00 | |||||
| S13-200/35 | 272 | 3320/3160 | 1.00 | |||||
| S13-250/35 | 320 | 3950/3760 | 0.95 | |||||
| S13-315/35 | 384 | 4750/4530 | 0.95 | |||||
| S13-400/35 | 464 | 5740/5470 | 0.85 | |||||
| S13-500/35 | 544 | 6910/6580 | 0.85 | |||||
| S13-630/35 | 664 | 7860 | 0.65 | |||||
| S13-800/35 | 784 | 9400 | 0.65 | |||||
| S13-1000/35 | 920 | 11500 | 0.65 | |||||
| S13-1250/35 | 1120 | 13900 | 0.60 | |||||
| S13-1600/35 | 1350 | 16600 | 0.60 | |||||
| S13-2000/35 | 1590 | 19700 | 0.55 | |||||
| S13-2500/35 | 1890 | 23200 | 0.55 | |||||
| Rated capacity (KVA) |
Join group label | Voltage combination | No-load current % |
No-load loss W |
Load loss (120℃)W |
Impedance voltage % |
||
|
High tension (KV) |
High-pressure tap range % |
Low pressure (KV) |
||||||
| SCB10-315/35 | Yyn0 or Dyn11 |
35 or 38.5 |
±5or ±2×2.5 |
0.4 3.15 6 6.3 10 10.5 11 |
2 | 1160 | 4170 | 6 7 8 9 |
| SCB10-400/35 | 2 | 1360 | 5360 | |||||
| SCBI10-500/35 | 2 | 1600 | 6590 | |||||
| SCB10-630/35 | 1.8 | 1840 | 7680 | |||||
| SCB10-800/35 | 1.9 | 2220 | 9350 | |||||
| SC810-1000/35 | 1.9 | 2640 | 10880 | |||||
| SCB10-1250/35 | 1.7 | 3090 | 12840 | |||||
| SCB10-1600/35 | 1.7 | 3650 | 15390 | |||||
| SCB10-2000/35 | 1.5 | 4200 | 18110 | |||||
| SCB10-2500/35 | 7.5 | 4800 | 21680 | |||||
| SCB10-3150/35 | 1.3 | 5000 | 24400 | |||||
| SC810-4000/35 | 1.3 | 6950 | 29330 | |||||
| SCB10-5000/35 | 1.1 | 8320 | 34770 | |||||
| SCB10-6300/35 | 1.1 | 9840 | 40630 | |||||
| SCB10-8000/35 | Yd11 or Ynd11 |
1 | 11200 | 45050 | ||||
| SCB10-10000/35 | 1 | 12800 | 51200 | 7 | ||||
| SC810-12500/35 | 0.9 | 16150 | 55300 | |||||
| SCB10-16000/35 | 0.8 | 19560 | 59800 | |||||
Partial discharge rarely announces itself with a bang. It begins as a microscopic electrical breakdown inside the insul...
READ MOREAnyone who has placed a purchase order for a large power transformer in the past few years knows the feeling. The techn...
READ MOREA boosting transformer is one of the least glamorous devices in an electrical room and one of the most useful. Instead ...
READ MOREA transformer tan delta test is the closest thing our industry has to a routine health check for insulation. Instead of...
READ MORE